This paper describes experimental studies on the seismic behavior and design of precast concrete buildings. A half-scale two-story precast concrete building incorporating a dual system and representing a parking structure in Mexico City was investigated. The structure was tested up to failure in a laboratory under simulated seismic loading. In some of the beam-to-column joints, the bottom longitudinal bars of the beam were purposely undeveloped due to dimensional constraints.

這篇文章是關于地震和預制混凝土建筑物設計的試驗性的研究。墨西哥市里一個帶有雙重系統(tǒng)和代表了一個停車場結構的未完工的兩層的預制混凝土建筑物被調查研究。這個結構物在實驗室里用模擬地震荷載測試,結果失敗了。在一些梁和柱的接頭處,粱底部的縱筋由于尺寸的限制不能屈服。這項研究所強調的是提高所測試結構物的可觀察的綜合性能。這種性能表現(xiàn)為所測試結構物的墻控制傳力途徑而且能顯著地減少預制結構所要求的側向變形。源自于這項研究的預制混凝土結構抗震設計標準和規(guī)范細節(jié)被討論。這項研究的最終結果是能更好地理解這種類型的建筑物的已得知的性能。
在墨西哥,一個兩層的預制混凝土構件建成的預制混凝土建筑物,在其上加上模擬的地震荷載。在這里描述的是其結果。在測試結構物中所選擇的結構系統(tǒng)是所謂的雙重類型,其定義就是構造墻的結合點以及梁-柱框架。測試結構物中預制梁柱之間的結合是窗型的。這種類型的建設顯著地用在低的或中等高建筑物中,在這種建筑中在每一樓層中柱子和窗子連在一起。這些“窗”包含頂部和底部的鋼筋。圖1所示的是在墨西哥市中這種類型的一個商業(yè)建筑物。
大多數(shù)的預制混凝土結構如圖1中所示,縱梁底部的鋼筋不能完全屈服。這是由于在梁-柱接頭中柱的尺寸限制所造成的。為了盡力克服這種缺陷,正如在后面所描述的,在墨西哥一些工程師嘗試著這樣設計這些接頭,就是通過用箍筋圈住這些鋼筋,這樣做是為了達到所要求的連續(xù)性。然而,這種嘗試在ACI建筑規(guī)范和MCBC中都沒有提到。這些研究的一部分是為了闡述這個觀點。
這項研究的目的是為了提高在實驗室里的預制混凝土結構屋的可觀察的性能以及為利用諭旨構件或預制結構建議了一個可接受的期望的抗震性能以及從建設能力的觀點所得出的有吸引力的特征。這篇文章中強調的所測試結構物中預制構件間的連接處的可觀察的性能以及預制樓層系統(tǒng)的性能將會詳細講述。
在過去的地震中,在建筑物中造成的可觀察的構造和非構造的破壞顯示了通過控制結構的側向位移來降低由地震造成的建筑物的破壞的重要性。在這里還要提到的是,在中等程度的地震中有一些情況下非結構構件的破壞相當大,盡管構造構件只有一點破壞或根本就沒有破壞。這種性能和結構物中所要求的過多的側向位移有關。